United States of America / English (change preferences)

Conductivity Cells

Our broad range of conductivity cells encompasses three measuring techniques: 2-electrode cells for µS/cm ranges, 4 and 6 electrode sensors for mS/cm levels and non-contact, electrode-less sensors.
Multi-electrode and electrode-less (toroidal) sensors tend to be used for applications with aggressive chemicals or where there can be sensor coating or fouling.
Comprehensive mounting methods are available to suit the majority of process applications: insertion, flow-through, immersion and retractable.



2-Electrode Contacting Cells - Range 0 to 10,000 µS/cm
High accuracy technique for trace conductivities from ultrapure water to industrial rinse waters. An alternating current is passed between two electrodes in contact with a solution. The transmitter converts the resultant potential difference into conductivity, concentration or specific resistance.


Table 1 of 3
AC211AC212AC213AC221
>>read more

>>read more>>read more
>>read more
2 electrode carbon/epoxy cells.  Fixed cable, terminal head and detachable.2-electrode carbon/epoxy cell.2-electrode carbon/epoxy cells.  AC213/0 submersible (top) AC213/1 immersion/dip (bottom).2-electrode, stainless steel, insertion cells with rapid temperature response
Electrode MaterialCarbonCarbonCarbonStainless steel
Cell Constant0.1 or 1.00.1 or 1.00.1 or 1.00.01 or 0.1
Temperature100°C (212°F)100°C (212°F)90°C (194°F)*200°C (392°F)**
Pressure6.6 bar (100psi)6.6 bar (100psi)--20 bar (290psi)
Submersion----10m
(AC213/0)
--
Immersion----1 or 2m
(AC213/1 & AC213/2)
--
Flow-Through--½ inch BSP or NPT--3/8 inch BSP or NPT
Screw-In Insertion1 inch BSP or NPT----¾ inch BSP or NPT
Retractable--------
Tri-Clamp Insertion--------
* AC213/1 & /2 only** When used with high temperature cable
Back >>


Table 2 of 3
22782085TB25TB254
>>read more>>read more>>read more>>read more
Electrode MaterialStainless steelStainless steelStainless steelStainless steel
Cell Constant0.050.05 or 0.10.01, 0.1 or 1.00.01, 0.1 or 1.0
Temperature130°C (266°F)110°C (230°F)175°C (347°F)100°C (212°F)
Pressure10.5 bar (150psi)10.5 bar (150psi)8.6 bar (125psi)6.9 bar (100psi)
Immersion---¾ inch NPT
Flow-Through----
Screw-In Insertion---1 inch NPT
Retractable-1½ inch BSP or NPT--
Tri-Clamp Insertion2 inch-1½, 2, 2½, 3 inch-
Back >>


Table 3 of 3
TB26TB264TB27
>>read more>>read more>>read more
Electrode MaterialStainless steelStainless steelStainless steel
Cell Constant0.01, 0.1 or 1.00.01, 0.1 or 1.00.01, 0.1 or 1.0
Temperature200°C (392°F)200°C (392°F)200°C (392°F)
Pressure6.9 bar (100psi)13.8 bar (200psi)20.7 bar (300psi)
Immersion½ inch NPT--
Flow-Through-½ inch NPT-
Screw-In Insertion¾ inch NPT--
Retractable1½ inch NPT-1½ inch NPT
Tri-Clamp Insertion---
Back >>


4-Electrode Contacting Cells - Range 0 to 2,000 mS/cm
Auto-compensating technology for high level conductivity and concentration measurements in high-coating processes. Provides an alarm when cleaning is required.
Table 1 of 2
TB451TB454TB457TB461
>>read more>>read more>>read more>>read more
Electrode MaterialStainless steelStainless steelStainless steelStainless steel
Temperature140°C (284°F)100°C (212°F)175°C (347°F)200°C (392°F)
Pressure6.9 bar (100psi)6.9 bar (100psi)8.6 bar (125psi)15.5 bar (225psi)
Immersion-¾ inch NPT-½ inch NPT
Flow-Through----
Screw-In Insertion-1 inch NPT-¾ inch NPT
Retractable--1¼ inch NPT
Tri-Clamp Insertion1 and 1½ inch-1½, 2, 2½, 3 inch-
Back >>

Table 2 of 2
TB464TB468TB47
>>read more>>read more>>read more
Electrode MaterialStainless steelHastelloy CStainless steel
Temperature200°C (392°F)Up to 140°C (284°F)200°C (392°F)
Pressure13.8 bar (200psi)Up to 6.9 bar (100 psig) 20.7 bar (300psi)
Immersion---
Flow-Through½ inch NPT--
Screw-In Insertion-¾ inch NPT-
Retractable-1 inch NPT1¼ inch NPT
Tri-Clamp Insertion---
Back >>

6-Electrode Contacting Cells - Range 0 to 500mS/cm
Auto-compensating technology for high level conductivity and concentration measurements in high-coating processes. Provides an alarm when cleaning is required.
222122412271
>>read more>>read more>>read more
Electrode MaterialCarbonCarbonCarbon
Temperature Sensor Pt1000Pt1000Direct contact Pt1000
Temperature100°C (212°F)100°C (212°F)100°C (212°F)
Pressure - 6.6 bar (100psi)6.6 bar (100psi)
Immersion0.9 m--
Flow-Through-½ inch BSP or NPT-
Screw-In Insertion--1 inch BSP or NPT
Hygienic fittings--DIN 11851 or Tri-clamp
Back >>

Electrodeless Sensors - Range 0 to 2,000 mS/cm
Non-contact technique providing immunity to polarisation, oily fouling and non-conducting coatings until gross fouling occurs. Measurement of the magnitude of induced AC into a closed loop of solution using two embedded toroids.
TB4042TB4043
>>read more>>read more
Body MaterialPEEKPEEK
Temperature200°C (392°F)121°C (250°F)
Pressure6.6 bar (100psi)6.6 bar (100psi)
Immersion¾ inch NPT-
Flow-Through--
Screw-In Insertion1½ inch NPT-
Rectractable1½ inch NPT-
Tri-Clamp Insertion-2 inch