pH & Redox/ORP Analyzers

ABB pH/Redox (ORP) analyzers are designed to meet the most exacting requirements of our valued customers. The extensive range covers 2 and 4-wire analyzers and single or dual-input devices.

Integral advanced functions include a sensor wash utility, PID control, automatic buffer recognition and in-line sensor diagnostics.

Our hazardous area certifications embrace FM, CSA and ATEX intrinsic safety. Instruments are available with HART, Profibus PA, and Fieldbus Foundation communications capabilities.

Single/Dual Input Analyzers (Table 1 of 2)
AX460AX466
>>read more>>read more
AX460 Thumbnail
Input 1pH/ORPpH/ORP
Input 2-pH/ORP
MountingPanel/Wall/PipePanel/Wall/Pipe
Application4-wire AC & 24V DC4-wire AC & 24V DC
Current Outputs2 or 4 2 or 4
Relay Outputs3 or 5 3 or 5
PID ControlYes-
Cleaning FunctionIncludedIncluded
Hazardous
Approval
- ATEX Type N (pending)
- FM/CSA Class 1
Div 2 (pending)
- ATEX Type N (pending)
- FM/CSA Class 1
Div 2 (pending)
Communication- Profibus DP
- Modbus (pending)
- Profibus DP
- Modbus (pending)


Single/Dual Input Analyzers (Table 1 of 2)
AX416AX436AX468
>>read more>>read more>>read more
AX416 ThumbnailAX416 Thumbnail
Input 1µS/cmmS/cmpH/ORP
Input 2pH/ORPpH/ORPppm DO
MountingPanel/Wall/PipePanel/Wall/PipePanel/Wall/Pipe
Application4-wire AC & 24V DC4-wire AC & 24V DC4-wire AC & 24V DC
Current Outputs2 or 4 2 or 4 2 or 4
Relays Outputs3 or 5 3 or 5 3 or 5
PID Control---
Cleaning FunctionIncludedIncludedIncluded
Hazardous
Approval
- ATEX Type N (pending)
- FM/CSA Class 1
Div 2 (pending)
- ATEX Type N (pending)
- FM/CSA Class 1
Div 2 (pending)
- ATEX Type N (pending)
- FM/CSA Class 1
Div 2 (pending)
Communication- Profibus DP
- Modbus (pending)
- Profibus DP
- Modbus (pending)
- Profibus DP
- Modbus (pending)

Single Input Analyzers
4630463146354636
>>read more>>read more>>read more>>read more
4630 Thumbnail4635 Thumbnail
Singel InputpH/ORPpH/ORPpH/ORPpH/ORP
MountingWall/PipeWall/PipePanelPanel
Application4-wire AC 4-wire AC 4-wire AC 4-wire AC
Current Outputs1 or 2 1 or 2 1 or 2 1 or 2
Relays Outputs2222
PID Control----
Cleaning Function-Included-Included
Hazardous
Approval
----
CommunicationModbusModbusModbusModbus

2-Wire and Other Analyzers
TB84PHTB82PH2410
>>read more>>read more>>read more
2410 Product Image
Single Input 1pH/ORPpH/ORPpH/ORP
MountingPanel/Wall/PipePanel/Wall/Pipe-
Application4-wire AC 2-wire 24V DCHandportable
Current Outputs2 1-
Relay Outputs3--
PID Control---
Cleaning FunctionIncluded--
Hazardous
Approval
FM & CSA Class I Div II- ATEX EEx ia IIC T3C
- FM & CSA Class I Div I, II
-
Communication-HART, PA, FF-

  • Rate this page
     
  • E-mail this page
     

Your preferences:

ABB contact for

United States of America