Insertion or hot-tap type, Hastelloy C electrodes.
Overview
The TB468 conductivity cell is available in either insertion (TB468-0) or hot tap styles (TB468-3).
The insertion style is also submersible. A Kynar (PVDF) body and Hastelloy C electrodes allow use in aggressive applications where 316 stainless steel is not advised.
KEY BENEFITS
Corrosion resistance
<p>designed for harsh, aggressive chemical applications</p>Advanced diagnostic capabilities
<p>extent of fouling notification & fouled sensor relay</p>Integral automatic temperature compensation
<p>ensure accurate readings</p>Installation flexibility
<p>several mounting styles suitable for all measurements</p>Technical Data
Details of two variants - TB468-0 and TB468-3
Measurement range (TB468-0) 0 - 2,000,000
<p>µS/cm</p>Maximum pressure (TB468-0) 6.89 bar
<p>100 psi</p>Maximum temperature (TB468-0) 50 °C
<p>122 °F</p>of variant TB468-3
Measurement range (TB468-3) 0 - 2,000,000
<p>µS/cm</p>Maximum pressure (TB468-3) 2.75 bar
<p>40 psi</p>Maximum temperature (TB468-3) 90 °C
<p>194 °F</p>Service